{"product_id":"4052899488182-oti-dali-50-220-240-1a4-lt2-fan","title":"4052899488182 - OTi DALI 50\/220…240\/1A4 LT2 FAN","description":"\u003ch6 class=\"headline headline--h6 headline--normalized\"\u003eProduct benefits\u003c\/h6\u003e\n\u003cul class=\"list\"\u003e\n\u003cli\u003eVersatile DALI window driver due to flexible output characteristic\u003c\/li\u003e\n\u003cli\u003eVery high efficiency\u003c\/li\u003e\n\u003cli\u003eProtection of the system thanks to thermal management and Smart Control\u003c\/li\u003e\n\u003cli\u003eHigh-quality dimming of 1…100 % by amplitude dimming\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eVersatile scope of application due to OSRAM DALI Technology:\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"list\"\u003e\n\u003cul class=\"simplelist\"\u003e\n\u003cli\u003eEasy to use in corridors and restrooms because of three-level Corridor function\u003c\/li\u003e\n\u003cli\u003eTouch DIM application: easy to control via pushbutton or sensor\u003c\/li\u003e\n\u003cli\u003eEnergy efficient Touch DIM operation due to automatic switch-off at sufficient residual light\u003c\/li\u003e\n\u003cli\u003eSuitable for emergency Installations (acc. to EN 60598-2-22 and IEC 61347-2-13, appendix J) thanks to DC detection (0 Hz, pulsating DC), on\/off switchable\u003c\/li\u003e\n\u003cli\u003eFeedback of power consumption and operating hours (Fit for SMART GRID)\u003c\/li\u003e\n\u003cli\u003eSuitable for buildings according to EPBD\/BREEAM\/LEED due to automatic Constant Lumen Output setting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch6 class=\"headline headline--h6 headline--normalized\"\u003eAreas of application\u003c\/h6\u003e\n\u003cul class=\"list\"\u003e\n\u003cul class=\"list\"\u003e\n\u003cli\u003eInstallation in emergency lighting systems according to IEC 61347-2-13, appendix J\u003c\/li\u003e\n\u003cli\u003eSuitable for use in luminaires with flexible current setting (DALI, CLO, LEDset)\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor SELV installations\u003c\/li\u003e\n\u003cli\u003eSuitable for luminaires of protection classes I and II\u003c\/li\u003e\n\u003cli\u003eSuitable for downlights, spotlights and LED panels\u003c\/li\u003e\n\u003cli\u003eInstallation via Cable Clamp Kit possible (depending on version of product)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch6 class=\"headline headline--h6 headline--normalized\"\u003eProduct features\u003c\/h6\u003e\n\u003cul class=\"list\"\u003e\n\u003cul class=\"list\"\u003e\n\u003cli\u003eSupply voltage: 220…240 V\u003c\/li\u003e\n\u003cli\u003eLine frequency: 0 Hz | 50 Hz | 60 Hz\u003c\/li\u003e\n\u003cli\u003eLine voltage: 198…264 V\u003c\/li\u003e\n\u003cli\u003eSafety according to EN 61347-1, 61347-2-3, 61347-2-13, 62384\u003c\/li\u003e\n\u003cli\u003eRI suppression: to EN 55015\/CISPR 15\u003c\/li\u003e\n\u003cli\u003eLine harmonics according to EN 61000-3-2\u003c\/li\u003e\n\u003cli\u003eImmunity according to EN 61547\u003c\/li\u003e\n\u003cli\u003eLifetime: up to 100,000 h\u003c\/li\u003e\n\u003cli\u003eType of protection: IP20\u003c\/li\u003e\n\u003cli\u003eIndependent connection via through-looping (except OTi DALI 15)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch6 class=\"headline headline--h6 headline--normalized\"\u003eElectrical data\u003c\/h6\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal wattage\u003c\/td\u003e\n\u003ctd\u003e50.00 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output power\u003c\/td\u003e\n\u003ctd\u003e55 W\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e220…240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e15…54 V\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e2)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage AC\u003c\/td\u003e\n\u003ctd\u003e198…264 V\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e3)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage DC\u003c\/td\u003e\n\u003ctd\u003e176…276 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eU-OUT (working voltage)\u003c\/td\u003e\n\u003ctd\u003e60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal current\u003c\/td\u003e\n\u003ctd\u003e0.27 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output current\u003c\/td\u003e\n\u003ctd\u003e600…1400 mA\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e4)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush current\u003c\/td\u003e\n\u003ctd\u003e30 A\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current tolerance\u003c\/td\u003e\n\u003ctd\u003e±3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput ripple current (100 Hz)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 %\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e6)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains frequency\u003c\/td\u003e\n\u003ctd\u003e0\/50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal harmonic distortion\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 %\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e7)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower factor λ\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 0.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECG efficiency\u003c\/td\u003e\n\u003ctd\u003e91 %\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e8)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice power loss\u003c\/td\u003e\n\u003ctd\u003e7.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. ECG no. on circuit breaker 10 A (B)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. ECG no. on circuit breaker 16 A (B)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. ECG no. on circuit breaker 25 A (B)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge capability (L\/N-Ground)\u003c\/td\u003e\n\u003ctd\u003e2 kV\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e9)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge capability (L-N)\u003c\/td\u003e\n\u003ctd\u003e1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss in stand-by mode\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlickering metric (Pst LM)\u003c\/td\u003e\n\u003ctd\u003e≤1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Shorters UK","offers":[{"title":"Default Title","offer_id":53580760645969,"sku":"4052899488182","price":75.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/1222\/5617\/files\/Screenshot2026-04-20163725.png?v=1776699474","url":"https:\/\/www.shortersuk.com\/products\/4052899488182-oti-dali-50-220-240-1a4-lt2-fan","provider":"Shorters UK","version":"1.0","type":"link"}