PureVOLT IUV-2S60-M4-LD
This Philips electronic ballast runs the following lamps :
Philips TUV 55W HO G55T8
Philips TUV 75W HO G75T8
Philips TUV PL-L 35W HO/4P
Philips TUV PL-L 60W HO/4P
Philips TUV PL-L 95W HO/4P
Philips TUV 36 T5 HO 75W 4P-SE
Detailed product description
Advance Pure Volt IUV-2S60-M4-L
The microprocessor controlled Advance PureVOLT electronic ballasts are specifically designed to operate a variety of germicidal lamps. PureVOLT ballasts operate the following low pressure mercury germicidal UV lamps:High OutputTwin Tube: (1 or 2) HO 35W or 60W; (1) HO 95WLinear: (1 or 2) 36T5HO (75W); (1) 64T5HO (145W)
Standard OutputTwin Tube: (1 or 2) TUV 18 PL-L or 36 PL-L
The Advance PureVOLT ballasts for UV lamps offer exclusive features such as IntelliVolt® technology (allowing the ballast to operate at any input voltage from 120 to 277 volts, 50/60 Hz), dual entry, color-coded connectors and lamp EOL protection.A powerful pair, the combination of germicidal lamps with an Advance PureVOLT ballast provides the appropriate level of UV-C energy to stop the spread of microorganisms, airborne contaminants, and pathogens, reducing the threat of illness andhelping to ensure a safer environment for building occupants.
Other options
TUV 55W HOTUV 75W HOTL 60W/10TL 80W/10
Product parameters
Drivers for TUV
Manufacturer
Philips
EAN
8727900783995
Product number
914499999001
Source type
IUV-2S60-M4-LD
Number of sources
1 or 2
Type
UIV-2S60-M4-LD
GPC code
914499999001
EOC code
872790078399500
Pieces in box
20ks
Voltage
120-277 V
Current
0,56 - 1,3 A
Length
175 mm
Height
34 mm
Width
77 mm
IP protection
IP20
Dimmable
No
Philips Electronic HF performer II TL-D ballast to run 1x58w or 1 x70W T8 Tubes - HFP158TLDEII
Specifications
General information
Application Code
III
Type Version
IDC
Lamp Type
TL-D/PL-L
Number of Lamps
1 piece/unit
Number of Products on MCB (16A Type B) (Nom)
28
Automatic Restart
Yes
Operating and electrical
Input Voltage
220 to 240 V
Input Frequency
50 to 60 Hz
Operating Frequency (Nom)
45 kHz
Ignition Method
Programmed Start
Crestfactor (Max)
1.7
Power Factor 100% Load (Nom)
0.99
Ignition Time (Max)
0.9 s
Mains Voltage Performance (AC)
-8%-+6%
Mains Voltage Safety (AC)
-10%-+10%
Earth Leakage Current (Nom)
0.5 mA
Inrush Current Width
0.25 ms
Constant Wattage Deviation
-2%/+2%
Ballast Factor (Nom)
0.95
Power Factor (Nom)
0.99
Power Losses (Nom)
4.3-4.4 W
Inrush Current Peak (Max)
18 A
Efficiency at full load [%]
93.3 %
Wiring
Connector Type Input Terminals
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable Capacity Output Wires Mutual (Nom)
200 pF
Connector Type Output Terminals
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable Length Hot Wiring
0.75 m
Wire Striplength
8.0-9.0 mm
Dual Fixture Master/Slave
Not applicable [ Master/Slave oper. not applicable]
Input Terminal Cross Section
0.50-1.00 mm²
Output Terminal Cross Section
0.50-1.00 mm²
Cable Capacity Output Wires to Earth (Nom)
200 pF
System characteristics
Rated Ballast-Lamp Power
58 W
Rated Lamp Power on TL-D
58 W
System Power on TL-D
56.3W@58W; 63.8W@70 W
Lamp Power on TL-D
51.9W@58W; 59.6W@70 W
Power Loss on TL-D
4.4W@58W; 4.3W@70 W
System Power on PL-L
55.8W@55 W
Lamp Power on PL-L
51.5W@55 W
Power Loss on PL-L
4.3W@55 W
Temperature
T-Ambient (Max)
60 °C
T-Ambient (Min)
-25 °C
T-Storage (Max)
50 °C
T-Storage (Min)
-40 °C
T-Case Lifetime (Nom)
80 °C
T-Case Maximum (Max)
80 °C
T-Ignition (Max)
60 °C
T-Ignition (Min)
-25 °C
Mechanical and housing
Housing
L 280x30x28
Emergency operation
Nominal Light Output After 60 Seconds
100% of EBLF
Battery Voltage Lamp Ignition
186-275 V
Normal Operating Voltage (DC)
220-240 V
Battery Voltage Lamp Operation
186-275
Battery Voltage Guaranteed Operation
176-275 V
Battery Voltage Guaranteed Ignition
186-275 V
Emergency Ballast Lumen Factor (EBLF) (Nom)
100 %
Nominal Light Output After 5 Seconds
50% of EBLF
Approval and application
Energy Efficiency Index
A2 BAT
IP Classification
IP 20 [ Ingress Protection 20]
EMI 9 kHz ... 30 MHz
EN55015
EMI 30 MHz ... 1000 MHz
EN55022 level B
Safety Standard
IEC 61347-2-3
Performance Standard
IEC 60929
Quality Standard
ISO 9000:2000
Environmental Standard
ISO 14001
Harmonic Current Emission Standard
IEC 61000-3-2
EMC Immunity Standard
IEC 61547
Vibration Standard
IEC68-2-6 F c
Bumps Standard
IEC 68-2-29 Eb
Humidity Standard
EN 61347-2-3 clause 11
Approval Marks
CE marking
ENEC certificate
VDE-EMV certificate
Temperature Marking
Yes
Emergency Standard
IEC 60598-2-22
Hum And Noise Level
< 30 dB(A)
Product data
Full product code
872790091170100
Order product name
HF-P 158 TL-D III 220-240V 50/60Hz IDC
EAN/UPC - Product
8711500999702
Order code
913713031866
Numerator - Quantity Per Pack
1
Numerator - Packs per outer box
12
Material Nr. (12NC)
913713031866
Net Weight (Piece)
0.205 kg
Installation diagrams
HF-P 158 TL-D III 220-240V 50/60Hz IDC
HF-P 158 TL-D III 220-240 V 50/60 Hz IDC
No Capacitor or Ignitor required with this ballast as built in
This item is now obsolete , we do however still have the RSF355245 exactly the same functionality just a different shape .
Please see Alternative , this is what you will be sent if you order the RSD355245
Magnetic Ballast Electrical Data Lamp Watts (W) 35 55 Lamp Current (A) 0.6 0.59 Input Voltage at 50Hz 240 240 Circuit Watts (W) 50 69 Running Current (A) 0.23 0.32 Delta T (°C) 50TA 50TA Thermal Cut-out N Capacitor Value (µf) 8 6 Capacitor Voltage (V) 250 250 Physical Data Dimensions (LxWxH mm) 144x65x51 Fixings (mm) 130 Weight (kg) 1.3
Please note this ballast does not require an ignitor
Digital Dimming Ballast to run 2 X 21/39w T5 tubes - PCA 2x21/39 T5 ECO - 22185102
Product description
Processor-controlled ballast with xitec II inside
Highest possible energy class CELMA EEI = A1 BAT (1)
Noise-free precise control via DALI or DSI signal, switchDIM or corridorFUNCTION
Nominal lifetime up to 100,000 h (at ta 50 °C with a failure rate ≤ 0.2 % per 1,000 h)
Multilamp management
OEM-specific reserved memory areas
5 years guarantee
Interfaces
DALI
DSI
switchDIM (with memory function + selectable dimming rate)
corridorFUNCTION (3 preprogrammed profiles)
Integrated SMART interface for function with SMART Sensor 5D 19f and corridorFUNCTION plugs
Functions
Intelligent Temperature Guard (overtemperature protection)
Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)
Optimum filament heating in any dimmer setting
Disconnection of filament heating from a dimming level of approx. 90 % for maximum energy efficiency (SMART-Heating concept)
corridorFUNCTION with ambient light control
Automatically triggered emergency lighting value in DC mode, 15 %
For emergency lighting systems as per EN 50172
Automatic start after replacement of defective lamps
Automatic shutdown if the lamp is faulty
Ballasts catalogue
Lifetime up to (h): 50000
Dimming range: 3 % – 100 %
Input voltage: 220 V – 240 V
Lamp type: TC-DE/TC-TE (26 W / 32 W / 42 W) This will also work on 18W PLL and 24W PLL
Start options: Warm start
Technical
Length (mm)
123
Height (mm)
28
Width (mm)
79
Dimming
DALI
Energy efficiency class
A1 BAT
Fixing length