View Datasheet
General Information
Application Code
III
Lamp Type
PL-T/C
Number of Lamps
2 piece/unit
Number of Products on MCB (16A Type B) (Nom)
28
Automatic Restart
Yes
Operating and Electrical
Input Voltage
220 to 240 V
Input Frequency
50 to 60 Hz
Operating Frequency (Max)
- kHz
Operating Frequency (Min)
42 kHz
Operating Frequency (Nom)
45 kHz
Ignition Method
Warm Start
Crestfactor (Max)
1.7
Power Factor 100% Load (Nom)
0.95
Ignition Time (Max)
0.40 s
Mains Voltage Performance (AC)
-8%-+6%
Mains Voltage Safety (AC)
-10%-+10%
Earth Leakage Current (Nom)
0.5 mA
Inrush Current Width
0.250 ms
Constant Wattage Deviation
-2%/+2%
Ballast Factor (Nom)
1
Power Losses (Nom)
0.68-2.21 W
Inrush Current Peak (Max)
18 A
Efficiency at full load [%]
87.97 %
Stock clearance, buy fast whilst stocks last
The Osram QTP-DL 2x36-40/220-240 is a non dimmable high frequency ballast to run 2 x 36 or 40w Long single turn PL-L compact fluorescent lamp.
Digital Dimming Ballast to run 1 X 28/54w T5 tubes - PCA 1x28/54 T5 ECO - 22185099
Product description _ Processor-controlled ballast with yII inside _ Highest possible energy class CELMA EEI = A1 BAT 1 _ Noise-free precise control via DALI or DSI signal, switchDIM or corridorFUNCTION _ Nominal lifetime up to 100,000 h (at ta 50 °C with a failure rate ≤ 0.2 % per 1,000 h) _ Multilamp management _ OEM-specific reserved memory areas _ 5 years guarantee Interfaces _ DALI _ DSI _ switchDIM (with memory function + selectable dimming rate) _ corridorFUNCTION (3 preprogrammed profiles) _ Integrated SMART interface for function with SMART Sensor 5D 19f and corridorFUNCTION plugs _ SMART interface for SMART plug cF – for setting the corridorFUNCTION profiles _ SMART interface for SMART sensor with daylight control Functions _ Intelligent Temperature Guard (overtemperature protection) _ Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown) _ Optimum filament heating in any dimmer setting _ Disconnection of filament heating from a dimming level of approx. 90 % for maximum energy efficiency (SMART-Heating concept) _ corridorFUNCTION with ambient light control _ Automatically triggered emergency lighting value in DC mode, 15 % _ For emergency lighting systems as per EN 50172 _ Automatic start after replacement of defective lamp
The Philips HF-P 3/414 TL5 is a fixed output high frequenct ballast for use with 3/4 x 14w flourescent lamp. This ballast has a flicker free warm start, electrode heating cut off, Low energy consumption and automatic stop circuit (stop start). The Philips HF-P is often used in Department stores, Airports, Railway stations, Hotels and Hospitals. It is also suitable for emergency installations.
Obsolete, please use the below as a viable alternative. This is what you will be sent .
Alternative
The Tridonic PC 1x18-24 W Basic (Linear) is a basic non-dimmable high frequency ballast to run: 1 x 24 Watt T5 Fluorescent tube OR 1 x 18 Watt T8 Fluorescent tube OR 1 x 22 Watt T5 circular fluorescent tube OR 1 x 18 Watt F shaped compact fluorescent 1 x 24 Watt F shaped compact fluorescent OR 1 x 18 Watt long single turn compact fluorescent 1 x 24 Watt long single turn compact fluorescent Tridonic 22176001!
Linear Electronic Ballast T5 24W , 2G11 18-24W, T8 14-15-18W
Description- Compact size electronic ballast for built-in use - Suitable for connection to emergency equipment in compliance with EN-60598-2-22 - Can be used for lighting equipment in protection Class l and ll - Push in connector with retaining springs. Connector cross section 0.5 - 1.5 mm2 - Start with pre-heating for longer lamp life (cut-off function) - Protection against lamp disconnection (re-start with pre-heating), lamp failure or end of life - Ballast can be secured with slots for M4 screws
Specification
Lamp
T5
Cap
G5
Power (W)
24
Length (mm)
150
Width (mm)
22
Height (mm)
19
DATA SHEET
Osram QTI 2X14/24/21/39
Areas of applicationPRODUCT DATASHEETQTi 2X14/24/21/39 GIIQUICKTRONIC® INTELLIGENT | ECG for FL 16mmProduct benefitsProduct features− Emergency lighting systems acc. to EN 50172 / DIN VDE 0108-100− Industry− Open-plan offices, corridors and storage rooms− Public buildings− Sports halls and factories− Strip lighting− Suitable for emergency lighting (DC operation)− Modernization of existing systems− Suitable for luminaires of protection classes I an