913700626566
HF-R 2 26-42 PL-T/C EII 220-240V 50/60Hz Compact, high-frequency electronic dimming ballast, using the analog protocol (1-10 V) for PL-T, PL-C and PL-R lamps;The ballast is primarily designed for Indoor application. For outdoor application, the luminaire should be minimum ClassⅠand need to be sufficiently protected against water & dust. The installation should also be guard against any lightening surge or any other necessary electrical protection as deemed in such typical installation & application. Product data General information Application Code EII Type Version mk3 Lamp Type PL-T/C Number of Lamps 2 piece/unit Number of Products on MCB (16A Type B) (Nom) 12 Automatic Restart Yes Operating and electrical Input Voltage 220 to 240 V Input Frequency 50 to 60 Hz Operating Frequency (Max) 100 kHz Operating Frequency (Min) 40 kHz Ignition Method Programmed Start Crestfactor (Max) 1.7 Power Factor 100% Load (Nom) 0.95 Ignition Time (Max) 1.5 s Mains Voltage Performance (AC) -8%-+6% Mains Voltage Safety (AC) -10%-+10% Earth Leakage Current (Max) 0.5 mA Inrush Current Width 0.35 ms Constant Wattage Deviation -2%/+2% Ballast Factor (Nom) 0.99 Power Losses (Nom) 6.5-7.5 W Inrush Current Peak (Max) 45 A Efficiency at full load [%] 93.58 % Wiring Connector Type Input Terminals Insert Cable Capacity Output Wires Mutual (Nom) 30 pF Connector Type Output Terminals Insert Connector Type Control Input Terminals Insert Wire Striplength 7.5-8.5 mm Dual Fixture Master/Slave Not advisable [ Master/Slave operation not advised] Control Input Terminal Cross Section 0.50-1.50 mm² Input Terminal Cross Section 0.50-1.50 mm² Datasheet, 2022, January 14 data subject to change Lighting Lighting Output Terminal Cross Section 0.50-1.50 mm² Cable Capacity Output Wires to Earth (Nom) 75 pF System characteristics Rated Ballast-Lamp Power 26-42 W Temperature T-Ambient (Max) 50 °C T-Ambient (Min) -20 °C T-Storage (Max) 80 °C T-Storage (Min) -25 °C T-Case Lifetime (Nom) 65 °C T-Case Maximum (Max) 75 °C Stable Lamp Operation Temperature Not Specied T-Ignition (Max) 50 °C T-Ignition (Min) 0 °C Controls and dimming Control Interface 1-10V Regulating Level Power 1%-100% Control Input Protection Yes (Basic insulation) Mechanical and housing Housing S 123x79x33 Emergency operation Battery Voltage Lamp Ignition 198-254 V Battery Voltage Lamp Operation 176-254 Approval and application Energy Efficiency Index A1 BAT IP Classification IP 20 [ Ingress Protection 20] EMI 9 kHz ... 30 MHz EN55015 EMI 30 MHz ... 1000 MHz EN55022 level B Safety Standard IEC 61347-2-3 Performance Standard IEC 60929 Quality Standard ISO 9000:2000 Environmental Standard ISO 14001 Harmonic Current Emission Standard IEC 61000-3-2 EMC Immunity Standard IEC 61547 Vibration Standard IEC68-2-6 F c Bumps Standard IEC 68-2-29 Eb Humidity Standard EN 61347-2-3 clause 11 Approval Marks CE marking ENEC certicate VDE-EMV certicate Temperature Marking Yes Emergency Standard IEC 60598-2-22 Hum And Noise Level Inaudible Product data Full product code 872790080972500 Order product name HF-R 2 26-42 PL-T/C EII 220-240V 50/60Hz EAN/UPC - Product 8711500880758 Order code 913700626566 Numerator - Quantity Per Pack 1 Numerator - Packs per outer box 12 Material Nr. (12NC) 913700626566 Net Weight (Piece) 0.23
This item is now obsolete, we will send out the below as a viable alternative
Alternative
Product Details
High frequency digital ballast in a compact matchbox form factor for single lamp operation. Automatic start after replacement of defective lamps. Safety shutdown of defective lamps and at end of lamp life.
· Suitable for single lamp operation
· Runs 28w TC-DD, 26w TC-D and TC-T lamps
· 5 year guarantee
· IP20
· 50,000hr life
Technical Specifications
Control Gear Type
High Frequency
Accessory Type
Ballast
Wattage
26 W
Wattage
26 W
Manufacturer
Tridonic
Dimming?
Non-Dimmable
No. Of Lamps
Single (1x)
Depth
21 mm
Length
145 mm
Type
Control Gear
Voltage
220-240 Volt
Width
22 mm
Compatible Lamp Type
T5C
Compatible Lamp Type
PLT (4 Pin)
Compatible Lamp Type
T5
Compatible Lamp Type
T8
Compatible Lamp Type
2D (4 Pin)
Control Gear Technology
Fluorescent
Manufacturers Part Number
22176002
Manufacturers Part Number
PC Basic 1x26SL
Manufacturers Part Number
22176002
PT-FIT 70/220…240 S
Product benefits
Optimized cost/benefit factor
Compact dimensions and low weight for small luminaire designs
Automatic safety shutdown of lamps in the event of a defect or at end of life (EoL)
View all details
Product data sheet
HID-PV XT 45 CPO Q 208-277V - PVXT45CPOQ - 871829166896100
Input Voltage
208-240-277 V
Line Frequency
50 to 60 Hz
Input Frequency
50 to 60 Hz
Earth Leakage Current (Max)
0.7 mA
Inrush Current Width
0.24 ms
Input Current (Nom)
0.26 A
Inrush Current Peak (Max)
28 A
Number of Products on MCB (16A Type B) (Nom)
5
66205100
Specifications
General Information
Remarks
UK importer address: Signify Commercial UK Limited, 3, Guildford Business Park, GU2 8XG
Application code
E+
Type version
mk2
Lamp type
TL5
Number of lamps
1 piece/unit
Number of products on MCB (16 A type B) (nom.)
39
Automatic restart
Yes
Operating and Electrical
Input Voltage
195-240 V
Input frequency
50 to 60 Hz
Operating frequency (max.)
110 kHz
Operating frequency (min.)
45 kHz
Ignition method
Warm Start
Crest factor (max.)
1.7
Power factor 100% load (nom.)
0.95
Ignition time (max.)
1 s
Mains voltage performance (AC)
-8%-+6%
Mains voltage safety (AC)
-10%-+10%
Earth leakage current (max.)
0.5 mA
Inrush current width
0.18 ms
Standby power consumption (max.)
0.25 W
Ballast factor (nom.)
1
Power losses (nom.)
3.8 W
Inrush current peak (max.)
20 A
Wiring
Connector type input terminals
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable capacity output wires mutual (max.)
200 pF
Connector type output terminals
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Connector type control input terminals
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Wire strip length
8.0-9.0 mm
Dual fixture master/slave
Yes [ Master/Slave operation possible]
Control input terminal cross section
0.50-1.00 mm²
Input terminal cross section
0.50-1.00 mm²
Output terminal cross section
0.50-1.00 mm²
Auto-insert (ALF/ADS) wire cross section
0.75 mm²
Cable capacity output wires to earth (max.)
200 pF
System characteristics
Rated ballast-lamp power
28-35-49-54 W
Rated lamp power on TL-D
58 W
System power on TL-D
55.5 W
Lamp power on TL-D
52.2 W
Power loss on TL-D
3.3 W
Rated lamp power on PL-L
55 W
System power on PL-L
54.6 W
Lamp power on PL-L
51.2 W
Power loss on PL-L
3.4 W
Rated lamp power on TL5
28/35/49/54 W
System power on TL5
32.1/39.1/55.1/57.7 W
Lamp power on TL5
29.4/36.4/51.6/54.8 W
Power loss on TL5
2.7/3.0/3.5 W
Rated lamp power on TL5 ECO
25/32/45/50 W
System power on TL5 ECO
29.4/33.1/49.1/54.2/ W
Lamp Power on TL5 ECO
26.3/30.2/45.7/50.4 W
Rated lamp power on TL-D ECO
51 W
System power on TL-D ECO
45.8 W
Power loss on TL-D ECO
3.1 W
Lamp power on TL-D ECO
42.7 W
Power loss on TL5 ECO
3.1/2.9/3.4/3.8/ W
Temperature
T-ambient (max.)
50 °C
T-ambient (min.)
-25 °C
T storage (max.)
80 °C
T storage (min.)
-40 °C
T case lifetime (max.)
75 °C
T-Case maximum (max.)
75 °C
Stable lamp operation temperature
15°C
T-Ignition (max.)
50 °C
T-Ignition (min.)
-25 °C
Controls and Dimming
Control interface
TD
Regulating level power
1%-100%
Control input protection
Yes (Basic insulation)
Mechanical and Housing
Housing
L 359x30x21
Emergency Operation
Battery voltage lamp ignition
198-254 V
Battery voltage lamp operation
176-254
Approval and Application
Energy efficiency index
A1 BAT
IP classification
IP 20 [ Ingress Protection 20]
EMI 9 kHz ... 30 MHz
EN55015
EMI 30 MHz ... 1,000 MHz
EN 55022 Class B
Safety standard
IEC 61347-2-3
Performance standard
IEC 60929
Quality standard
ISO 9000:2000
Environmental standard
ISO 14001
Harmonic current emission standard
IEC 61000-3-2
EMC immunity standard
IEC 61547
Vibration standard
IEC68-2-6 F c
Bumps standard
IEC 68-2-29 Eb
Humidity standard
EN 61347-2-3 clause 11
Approval marks
CE marking
ENEC certificate
VDE-EMV certificate
Temperature marking
Yes
Emergency standard
IEC 60598-2-22
Humming and noise level
Inaudible
Product Data
Full product code
871829166205100
Order product name
HF-Ri TD 1 28/35/49/54 TL5 E+ 195-240V
EAN/UPC – product
8718291662051
Order code
66205100
Local order code
HFRITD12854T5PL
SAP numerator – quantity per pack
1
Numerator – packs per outer box
12
SAP material
913700695666
SAP net weight (piece)
0.261 kg
PureVOLT IUV-2S60-M4-LD
This Philips electronic ballast runs the following lamps :
Philips TUV 55W HO G55T8
Philips TUV 75W HO G75T8
Philips TUV PL-L 35W HO/4P
Philips TUV PL-L 60W HO/4P
Philips TUV PL-L 95W HO/4P
Philips TUV 36 T5 HO 75W 4P-SE
Detailed product description
Advance Pure Volt IUV-2S60-M4-L
The microprocessor controlled Advance PureVOLT electronic ballasts are specifically designed to operate a variety of germicidal lamps. PureVOLT ballasts operate the following low pressure mercury germicidal UV lamps:High OutputTwin Tube: (1 or 2) HO 35W or 60W; (1) HO 95WLinear: (1 or 2) 36T5HO (75W); (1) 64T5HO (145W)
Standard OutputTwin Tube: (1 or 2) TUV 18 PL-L or 36 PL-L
The Advance PureVOLT ballasts for UV lamps offer exclusive features such as IntelliVolt® technology (allowing the ballast to operate at any input voltage from 120 to 277 volts, 50/60 Hz), dual entry, color-coded connectors and lamp EOL protection.A powerful pair, the combination of germicidal lamps with an Advance PureVOLT ballast provides the appropriate level of UV-C energy to stop the spread of microorganisms, airborne contaminants, and pathogens, reducing the threat of illness andhelping to ensure a safer environment for building occupants.
Other options
TUV 55W HOTUV 75W HOTL 60W/10TL 80W/10
Product parameters
Drivers for TUV
Manufacturer
Philips
EAN
8727900783995
Product number
914499999001
Source type
IUV-2S60-M4-LD
Number of sources
1 or 2
Type
UIV-2S60-M4-LD
GPC code
914499999001
EOC code
872790078399500
Pieces in box
20ks
Voltage
120-277 V
Current
0,56 - 1,3 A
Length
175 mm
Height
34 mm
Width
77 mm
IP protection
IP20
Dimmable
No
Philips Electronic HF performer II TL-D ballast to run 1x58w or 1 x70W T8 Tubes - HFP158TLDEII
Specifications
General information
Application Code
III
Type Version
IDC
Lamp Type
TL-D/PL-L
Number of Lamps
1 piece/unit
Number of Products on MCB (16A Type B) (Nom)
28
Automatic Restart
Yes
Operating and electrical
Input Voltage
220 to 240 V
Input Frequency
50 to 60 Hz
Operating Frequency (Nom)
45 kHz
Ignition Method
Programmed Start
Crestfactor (Max)
1.7
Power Factor 100% Load (Nom)
0.99
Ignition Time (Max)
0.9 s
Mains Voltage Performance (AC)
-8%-+6%
Mains Voltage Safety (AC)
-10%-+10%
Earth Leakage Current (Nom)
0.5 mA
Inrush Current Width
0.25 ms
Constant Wattage Deviation
-2%/+2%
Ballast Factor (Nom)
0.95
Power Factor (Nom)
0.99
Power Losses (Nom)
4.3-4.4 W
Inrush Current Peak (Max)
18 A
Efficiency at full load [%]
93.3 %
Wiring
Connector Type Input Terminals
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable Capacity Output Wires Mutual (Nom)
200 pF
Connector Type Output Terminals
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable Length Hot Wiring
0.75 m
Wire Striplength
8.0-9.0 mm
Dual Fixture Master/Slave
Not applicable [ Master/Slave oper. not applicable]
Input Terminal Cross Section
0.50-1.00 mm²
Output Terminal Cross Section
0.50-1.00 mm²
Cable Capacity Output Wires to Earth (Nom)
200 pF
System characteristics
Rated Ballast-Lamp Power
58 W
Rated Lamp Power on TL-D
58 W
System Power on TL-D
56.3W@58W; 63.8W@70 W
Lamp Power on TL-D
51.9W@58W; 59.6W@70 W
Power Loss on TL-D
4.4W@58W; 4.3W@70 W
System Power on PL-L
55.8W@55 W
Lamp Power on PL-L
51.5W@55 W
Power Loss on PL-L
4.3W@55 W
Temperature
T-Ambient (Max)
60 °C
T-Ambient (Min)
-25 °C
T-Storage (Max)
50 °C
T-Storage (Min)
-40 °C
T-Case Lifetime (Nom)
80 °C
T-Case Maximum (Max)
80 °C
T-Ignition (Max)
60 °C
T-Ignition (Min)
-25 °C
Mechanical and housing
Housing
L 280x30x28
Emergency operation
Nominal Light Output After 60 Seconds
100% of EBLF
Battery Voltage Lamp Ignition
186-275 V
Normal Operating Voltage (DC)
220-240 V
Battery Voltage Lamp Operation
186-275
Battery Voltage Guaranteed Operation
176-275 V
Battery Voltage Guaranteed Ignition
186-275 V
Emergency Ballast Lumen Factor (EBLF) (Nom)
100 %
Nominal Light Output After 5 Seconds
50% of EBLF
Approval and application
Energy Efficiency Index
A2 BAT
IP Classification
IP 20 [ Ingress Protection 20]
EMI 9 kHz ... 30 MHz
EN55015
EMI 30 MHz ... 1000 MHz
EN55022 level B
Safety Standard
IEC 61347-2-3
Performance Standard
IEC 60929
Quality Standard
ISO 9000:2000
Environmental Standard
ISO 14001
Harmonic Current Emission Standard
IEC 61000-3-2
EMC Immunity Standard
IEC 61547
Vibration Standard
IEC68-2-6 F c
Bumps Standard
IEC 68-2-29 Eb
Humidity Standard
EN 61347-2-3 clause 11
Approval Marks
CE marking
ENEC certificate
VDE-EMV certificate
Temperature Marking
Yes
Emergency Standard
IEC 60598-2-22
Hum And Noise Level
< 30 dB(A)
Product data
Full product code
872790091170100
Order product name
HF-P 158 TL-D III 220-240V 50/60Hz IDC
EAN/UPC - Product
8711500999702
Order code
913713031866
Numerator - Quantity Per Pack
1
Numerator - Packs per outer box
12
Material Nr. (12NC)
913713031866
Net Weight (Piece)
0.205 kg
Installation diagrams
HF-P 158 TL-D III 220-240V 50/60Hz IDC
HF-P 158 TL-D III 220-240 V 50/60 Hz IDC
66205100
Specifications
General Information
Remarks
UK importer address: Signify Commercial UK Limited, 3, Guildford Business Park, GU2 8XG
Application code
E+
Type version
mk2
Lamp type
TL5
Number of lamps
1 piece/unit
Number of products on MCB (16 A type B) (nom.)
39
Automatic restart
Yes
Operating and Electrical
Input Voltage
195-240 V
Input frequency
50 to 60 Hz
Operating frequency (max.)
110 kHz
Operating frequency (min.)
45 kHz
Ignition method
Warm Start
Crest factor (max.)
1.7
Power factor 100% load (nom.)
0.95
Ignition time (max.)
1 s
Mains voltage performance (AC)
-8%-+6%
Mains voltage safety (AC)
-10%-+10%
Earth leakage current (max.)
0.5 mA
Inrush current width
0.18 ms
Standby power consumption (max.)
0.25 W
Ballast factor (nom.)
1
Power losses (nom.)
3.8 W
Inrush current peak (max.)
20 A
Wiring
Connector type input terminals
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable capacity output wires mutual (max.)
200 pF
Connector type output terminals
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Connector type control input terminals
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Wire strip length
8.0-9.0 mm
Dual fixture master/slave
Yes [ Master/Slave operation possible]
Control input terminal cross section
0.50-1.00 mm²
Input terminal cross section
0.50-1.00 mm²
Output terminal cross section
0.50-1.00 mm²
Auto-insert (ALF/ADS) wire cross section
0.75 mm²
Cable capacity output wires to earth (max.)
200 pF
System characteristics
Rated ballast-lamp power
28-35-49-54 W
Rated lamp power on TL-D
58 W
System power on TL-D
55.5 W
Lamp power on TL-D
52.2 W
Power loss on TL-D
3.3 W
Rated lamp power on PL-L
55 W
System power on PL-L
54.6 W
Lamp power on PL-L
51.2 W
Power loss on PL-L
3.4 W
Rated lamp power on TL5
28/35/49/54 W
System power on TL5
32.1/39.1/55.1/57.7 W
Lamp power on TL5
29.4/36.4/51.6/54.8 W
Power loss on TL5
2.7/3.0/3.5 W
Rated lamp power on TL5 ECO
25/32/45/50 W
System power on TL5 ECO
29.4/33.1/49.1/54.2/ W
Lamp Power on TL5 ECO
26.3/30.2/45.7/50.4 W
Rated lamp power on TL-D ECO
51 W
System power on TL-D ECO
45.8 W
Power loss on TL-D ECO
3.1 W
Lamp power on TL-D ECO
42.7 W
Power loss on TL5 ECO
3.1/2.9/3.4/3.8/ W
Temperature
T-ambient (max.)
50 °C
T-ambient (min.)
-25 °C
T storage (max.)
80 °C
T storage (min.)
-40 °C
T case lifetime (max.)
75 °C
T-Case maximum (max.)
75 °C
Stable lamp operation temperature
15°C
T-Ignition (max.)
50 °C
T-Ignition (min.)
-25 °C
Controls and Dimming
Control interface
TD
Regulating level power
1%-100%
Control input protection
Yes (Basic insulation)
Mechanical and Housing
Housing
L 359x30x21
Emergency Operation
Battery voltage lamp ignition
198-254 V
Battery voltage lamp operation
176-254
Approval and Application
Energy efficiency index
A1 BAT
IP classification
IP 20 [ Ingress Protection 20]
EMI 9 kHz ... 30 MHz
EN55015
EMI 30 MHz ... 1,000 MHz
EN 55022 Class B
Safety standard
IEC 61347-2-3
Performance standard
IEC 60929
Quality standard
ISO 9000:2000
Environmental standard
ISO 14001
Harmonic current emission standard
IEC 61000-3-2
EMC immunity standard
IEC 61547
Vibration standard
IEC68-2-6 F c
Bumps standard
IEC 68-2-29 Eb
Humidity standard
EN 61347-2-3 clause 11
Approval marks
CE marking
ENEC certificate
VDE-EMV certificate
Temperature marking
Yes
Emergency standard
IEC 60598-2-22
Humming and noise level
Inaudible
Product Data
Full product code
871829166205100
Order product name
HF-Ri TD 1 28/35/49/54 TL5 E+ 195-240V
EAN/UPC – product
8718291662051
Order code
66205100
Local order code
HFRITD12854T5PL
SAP numerator – quantity per pack
1
Numerator – packs per outer box
12
SAP material
913700695666
SAP net weight (piece)
0.261 kg
1 x TUV36T5HO - TUV60WPLL - TUV55WHO - TUV75WHO - GXO36T6PH
Lightwave UV Ballast - EB-1006-02LF (LW20EB65-G01S). This ballast has switch for 120 volt or 220/230 volt. Operates one germicidal lamp, Max Lamp Wattage: 75 watts, Lamp Voltage Range: 110-179 v, Lamp Current Range: 600-800 mA. Lamp type - GHO36, GXO36T6PH, TUV 55, 65, 75 W (PLL). Rapid start. Dimensions - Length (includes mounting tabs) 4.25" , Width - 2.25", Height 1.25". * No Wires, plug in wire ports, Case Size D. Model # EB-1006-02LF, Lightwave.
No Capacitor or Ignitor required with this ballast as built in
This item is now obsolete , we do however still have the RSF355245 exactly the same functionality just a different shape .
Please see Alternative , this is what you will be sent if you order the RSD355245
Magnetic Ballast Electrical Data Lamp Watts (W) 35 55 Lamp Current (A) 0.6 0.59 Input Voltage at 50Hz 240 240 Circuit Watts (W) 50 69 Running Current (A) 0.23 0.32 Delta T (°C) 50TA 50TA Thermal Cut-out N Capacitor Value (µf) 8 6 Capacitor Voltage (V) 250 250 Physical Data Dimensions (LxWxH mm) 144x65x51 Fixings (mm) 130 Weight (kg) 1.3
Please note this ballast does not require an ignitor
Please note this item is now obsolete , you will be sent a Philips alternative which is exactly the same size with the same terminals
This is the Tridonic PC 2/58 T8 Pro, a non-dimmable high frequency ballast to run 2 x 58w T8 fluorescent tube or 2 x 55w TC-L lamp.These ballasts have a nominal life time of up to 100,000 hours and provide a constant luminous flux even with fluctuations in mains voltage.Tridonic T8 Pro ballasts also have an automatic start after replacement of defective lamps and a safety shutdown of defective lamps at the end of a lamps life.