1 x TUV36T5HO - TUV60WPLL - TUV55WHO - TUV75WHO - GXO36T6PH
Lightwave UV Ballast - EB-1006-02LF (LW20EB65-G01S). This ballast has switch for 120 volt or 220/230 volt. Operates one germicidal lamp, Max Lamp Wattage: 75 watts, Lamp Voltage Range: 110-179 v, Lamp Current Range: 600-800 mA. Lamp type - GHO36, GXO36T6PH, TUV 55, 65, 75 W (PLL). Rapid start. Dimensions - Length (includes mounting tabs) 4.25" , Width - 2.25", Height 1.25". * No Wires, plug in wire ports, Case Size D. Model # EB-1006-02LF, Lightwave.
No Capacitor or Ignitor required with this ballast as built in
This item is now obsolete , we do however still have the RSF355245 exactly the same functionality just a different shape .
Please see Alternative , this is what you will be sent if you order the RSD355245
Magnetic Ballast Electrical Data Lamp Watts (W) 35 55 Lamp Current (A) 0.6 0.59 Input Voltage at 50Hz 240 240 Circuit Watts (W) 50 69 Running Current (A) 0.23 0.32 Delta T (°C) 50TA 50TA Thermal Cut-out N Capacitor Value (µf) 8 6 Capacitor Voltage (V) 250 250 Physical Data Dimensions (LxWxH mm) 144x65x51 Fixings (mm) 130 Weight (kg) 1.3
Please note this ballast does not require an ignitor
Please note this item is now obsolete , you will be sent a Philips alternative which is exactly the same size with the same terminals
This is the Tridonic PC 2/58 T8 Pro, a non-dimmable high frequency ballast to run 2 x 58w T8 fluorescent tube or 2 x 55w TC-L lamp.These ballasts have a nominal life time of up to 100,000 hours and provide a constant luminous flux even with fluctuations in mains voltage.Tridonic T8 Pro ballasts also have an automatic start after replacement of defective lamps and a safety shutdown of defective lamps at the end of a lamps life.
This item is now obsolete an alternative will be sent
This Osram QT-ECO 1x18-24/220-240 S is a non dimmable matchbox ballast to run: 1 x 24w T5 fluorescent tube 1 x 22w T5 Circular tube 1 x 15w or 18w T8 Fluorescent tube 1 x18w or 24w Double turn CFL's 1 x 18w or 24w DuluxW F CFL's
Digital Dimming Ballast to run 2 X 21/39w T5 tubes - PCA 2x21/39 T5 ECO - 22185102
Product description
Processor-controlled ballast with xitec II inside
Highest possible energy class CELMA EEI = A1 BAT (1)
Noise-free precise control via DALI or DSI signal, switchDIM or corridorFUNCTION
Nominal lifetime up to 100,000 h (at ta 50 °C with a failure rate ≤ 0.2 % per 1,000 h)
Multilamp management
OEM-specific reserved memory areas
5 years guarantee
Interfaces
DALI
DSI
switchDIM (with memory function + selectable dimming rate)
corridorFUNCTION (3 preprogrammed profiles)
Integrated SMART interface for function with SMART Sensor 5D 19f and corridorFUNCTION plugs
Functions
Intelligent Temperature Guard (overtemperature protection)
Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)
Optimum filament heating in any dimmer setting
Disconnection of filament heating from a dimming level of approx. 90 % for maximum energy efficiency (SMART-Heating concept)
corridorFUNCTION with ambient light control
Automatically triggered emergency lighting value in DC mode, 15 %
For emergency lighting systems as per EN 50172
Automatic start after replacement of defective lamps
Automatic shutdown if the lamp is faulty
Obsolete, If you are using the dali dimming feature please order the EL2X80IDIM , please note this is dali dimming only and not DSI dimming
Product description
Processor-controlled ballast with xitec II inside
Highest possible energy class CELMA EEI = A1 BAT (1)
Noise-free precise control via DALI or DSI signal, switchDIM or corridorFUNCTION
Nominal lifetime up to 100,000 h (at ta 50 °C with a failure rate ≤ 0.2 % per 1,000 h)
Multilamp management
OEM-specific reserved memory areas
5 years guarantee
Interfaces
DALI
DSI
switchDIM (with memory function + selectable dimming rate)
corridorFUNCTION (3 preprogrammed profiles)
Integrated SMART interface for function with SMART Sensor 5D 19f and corridorFUNCTION plugs
Functions
Intelligent Temperature Guard (overtemperature protection)
Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)
Optimum filament heating in any dimmer setting
Disconnection of filament heating from a dimming level of approx. 90 % for maximum energy efficiency (SMART-Heating concept)
corridorFUNCTION with ambient light control
Automatically triggered emergency lighting value in DC mode, 15 %
For emergency lighting systems as per EN 50172
Automatic start after replacement of defective lamps
Automatic shutdown if the lamp is faulty
Ballasts catalogue
Lifetime up to (h): 50000
Dimming range: 3 % – 100 %
Input voltage: 220 V – 240 V
Lamp type: TC-DE/TC-TE (26 W / 32 W / 42 W) This will also work on 18W PLL and 24W PLL
Start options: Warm start
Technical
Length (mm)
123
Height (mm)
28
Width (mm)
79
Dimming
DALI
Energy efficiency class
A1 BAT
Fixing length
100.5
Tridonic PC122642TCPRO Electronic compact ballast to run 1x18-42w - 1x22w - 2x18-26w TCT Pro
Tridonic are a world-leading supplier of lighting technology and support their customers with intelligent hardware and software solutions. Tridonic aim to make products which offer the highest level of quality, reliability and energy savings.
The Tridonic 22176408 PC TC PRO electronic fixed output ballast is designed for luminaires with 1 or 2 x 26-42W TC lamps. The ballast has a compact design and boasts a nominal life-time up to 100,000 hours.
The ballast offers a large temperature range and ensures constant luminous flux irrespective of fluctuations in mains voltage. Various functions and safety features are included, such as: Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown), Automatic start after replacement of defective lamps and Safety shutdown of defective lamps at end of life.