Liteplan

81 products

  • LITEPLAN - HRNT5/4/14+24-LP 14/24w T5 Emergency Module

    £52.19

  • LITEPLAN - HRN6-LP Emergency Module

    LITEPLAN LITEPLAN - HRN6-LP Emergency Module

    Emergency Module 6 Cell 4-100W Florescent ballast  Suitable for Most Compact Fluorescent Lamps • Deep Discharge Protection • Four Pole Changeover Relay • Fifth Pole Relay for Ballast Protection • High Temperature NiCd Batteries • Compact Module Dimensions • Can be Provided in Various Remote Enclosures • Operates One Lamp Within Multi Lamp Circuits A 3 hour emergency lighting conversion kit which operates with high temperature 7.2V NiCd batteries. The unit is designed to suit a wide range of fluorescent tubes. Order Codes HRN/6-K For the converison of fluorescent tubes from 4W to 125W. Supplied as module, battery and LED kit. HRN/6-R As above, but supplied within a suitable remote enclosure with a connecting loom. Technical Details: Mains Supply 230-240V AC 50/60 Hz Power Rating 22mA λ = 0.88 Emergency Duration 3 hours Battery Type 7.2V 4.5Ah NiCd Charge Current 200mA Cut-Off Voltage 6V Discharge Current 1.05 Amp Tc Point and Temperature 70 °C Case Side Module Dimensions (LxWxH) 165mm x 45mm x 29mm Battery Dimensions (LxØ) 2 x 220mm x 37mm Overall Kit Weight 1.1Kg  

    £47.91

  • LLS/6 Conversion 14W-80W T5 Kit Including Ni-CD Battery LLS/6-K

    liteplan LLS/6 Conversion 14W-80W T5 Kit Including Ni-CD Battery LLS/6-K

    LLS/6 Conversion Kit Now obsolete, you will be supplied with an OM680/Lp with the same batteries   A range of slim, Low Profile 3-hour emergency lighting conversion kits. Specifically designed for compact fluorescent and T5 lamps and for use within low profile extrusions due to it's 21mm high construction. The unit provides continuous lamp cathode heating and features a 4-pole change over relay plus additional 5th pole for HF control gear isolation/protection. The LLS/6 module automatically adjusts its output to the lamp being connected, therefore maximising the ballast lumen factor (BLF) achieved. Order Code Order Code  Lamps Battery Description LLS/6-K 14-80W * 7.2V 4.5Ah NiCd Supplied as Module, Battery and Charge Indicating LED

    £101.41

  • Liteplan HRN/3-K Conversion Kit Supplied with  3 Cell batteries

    LitePlan Liteplan HRN/3-K Conversion Kit Supplied with 3 Cell batteries

    The Liteplan HRN 3 Conversion Kit is a 3hr emergency lighting conversion kit suitable for 4-36w fluorescent lamps. This unit is to suit multiple 4-pin fluorescent lamp wattages and circuits. 4-pole change over relay plus additional 5th pole for HF ballast isolation. This conversion kit has these additional benefits :- 4-pole changeover relay, Additional 5th pole relay, Deep discharge protection, Low profile enclosure, Constant current charger, High temperature niCd cells. The HRN range is supplied in conversion kit form. They are supplied as standard with the following parts :- 500mm Green charge healthy LED indicator and mounting collar, 3/4/5 Cell kits are supplied with NiCd batteries and AMP irreversible battery connector.

    £74.74

  • DNA/1/TP40 Liteplan

    LitePlan DNA/1/TP40 Liteplan

    DNA/1/TP40 View Datasheet   Remote 2-part single-cell 3 hour DALI Self-Test emergency lighting conversion kit, designed to suit an extremely wide range of LED types and circuits, to suit 40mm aperture.  The DNA/1 automatically adjusts the output LED current to provide the best match between the battery and the load, providing maximum illumination whilst ensuring full battery duration This product is fully DALI compliant and in keeping with the DALI Standard, if the module is commissioned without a DALI control system present, the unit will revert the standalone self-test, indicating its faults via the charge LED.

    £79.97

  • Liteplan  NLP/1/80-K LED Emergency Conversion Pack, Integral Installation, LiFePO4 Battery,

    LITEPLAN Liteplan NLP/1/80-K LED Emergency Conversion Pack, Integral Installation, LiFePO4 Battery,

    he NLP range, is a high quality 3 hour switchable emergency lighting module designed to suit a wide range of LED types, circuits, and applications.  Liteplan tested and verify full compatibility with Ledison T8, T5 tube lights, GU10 spots and GLS LED bulbs.  KEY ELECTRICAL CHARACTERISTICS Module, Single Cell Battery and Charge LED Indicator for 6-55 Volt LED Loads Suitable for Mounting Inside the Luminaire Slim Module Suitable for Linear Applications Long Life LiFePO4 Batteries Strain Relief Module with Fitted Cables Suitable for a Wide Range of LED Loads TECHNICAL SPECIFICATIONS A 3 hour emergency lighting conversion kit which operates with Long Life LiFePO4 batteries. The unit is designed to suit an extremely wide range of LED types and circuits. The NLP/1 automatically adjusts the output LED current to provide the best match between the battery and the load, providing maximum illumination whilst ensuring full battery duration. The batteries used with this unit not only provide double the life of traditional emergency lighting batteries, but consume far less power during their operational life.   Mains Supply Voltage 230-240V AC 50/60Hz Emergency Duration 3 Hours Recharge Period 24 Hours LED Current Limit 320mA Battery Current Limit 1100mA Cut off Voltage 2.5V

    £64.04

  • Last stock! NLP/1/TP40 Remote Conversion Range / Kits

    LITEPLAN NLP/1/TP40 Remote Conversion Range / Kits

    Order Codes Please Select   Order Codes Order Code Description     NLP/1/TP40 6-55V module and single cell battery fitted with strain relief cables to module and battery   Suitable for wiring to the luminaire remotely. 40mm aperture     NLP/1/80/TP40 6-79V module and single cell battery fitted with strain relief cables to module and battery   Suitable for mounting inside the luminaire     NLP/1S/TP40 6-55V module and three cell battery fitted with strain relief cables to module and battery   Suitable for wiring to the luminaire remotely. 40mm Aperture     NLP/1S/80/TP40 6-79V module and three cell battery fitted with strain relief cables to module and battery   Suitable for mounting in damp or wet locations   The NLP/1/TP40, is a remote 3-hour switchable emergency lighting module designed to suit a wide range of LED types, circuits and applications. The unit operates with lithium iron phosphate (LiFePO4) batteries and is available in 2 versions, one for SELV applications, less than 60V and one up to 80V. The module automatically adjusts the output current to provide the best match between the battery and the load, providing maximum illumination whilst ensuring full battery duration. The module is supplied with a green charge healthy indicator LED. This range uses the latest LiFePO4 battery technology, dramatically reducing energy consumption and facilities management labour.  The NLP/1/TP40 is supplied with strain relief cables so that it can be installed adjacent to the luminaire in the ceiling void. The product passes through a 40mm, or greater aperture.    

    £56.47

  • HRN/6/55L Liteplan, obsolete, Like for like alternative will be sent please see below

    LITEPLAN HRN/6/55L Liteplan, obsolete, Like for like alternative will be sent please see below

    Obsolete you will be sent  ALTERNATIVE   For use with PLL55W DuluxL  55W Biax L 55W  Lynx L 55W Requires a 6 Cell battery  Battery 

    £49.20

  • Lite-Plan HRN/T5/6/35+49 Module -Obsolete 6 Cell alternative will be sent

    LitePlan Lite-Plan HRN/T5/6/35+49 Module -Obsolete 6 Cell alternative will be sent

    This item is obsolete please consider the  below as a viable alternative  ALTERNATIVE  The Lite-Plan HRN/T5/6/35+49 is a 3hr emergency lighting module. Specifically designed for use with 35w & 49w T5 fluorescent lamps.4-pole change over relay plus additional 5th pole for HF ballast isolation. This Lite-Plan conversion kit has the following benefits :- Specific T5 lamp calibration to maximise BLF%, 4 pole changeover relay, additional 5th pole relay, Deep discharge protection, Low profile enclosure, constant current charger and high temperature NiCd cells.

    £47.91

  • DNA/1 DALI Addressable Conversion Range

    LITEPLAN DNA/1 DALI Addressable Conversion Range

    Variants Description   Please note all the DNA kits are now D2N kits which is the exact same plus its Dali 2 Compatible  Order Codes Order Code Description DNA/1-K Module, Single Cell Battery and Charge LED Indicator for LED loads from 6-55Vf D2N/1 DNA/1S-K Module, Triple Cell Battery and Charge LED Indicator for LED loads from 6-55Vf D2N/1S DNA/1/TP40 Above Single Cell Kit Housed in a Two Part Enclosure for 40mm Apertures D2N/1/TP40 DNA/1S/TP40 Above Triple Cell Kit Housed in a Two Part Enclosure for 40mm Apertures D2N/1S/TP40     DNA/1/80-K Module, Single Cell Battery and Charge LED Indicator for LED loads from 6-80Vf DNA/1S/80-K Module, Triple Cell Battery and Charge LED Indicator for LED loads from 6-80Vf DNA/1/80/TP40 Above Single Cell Kit Housed in a Two Part Enclosure for 40mm Apertures DNA/1S/80/TP40 Above Triple Cell Kit Housed in a Two Part Enclosure for 40mm Apertures

    £67.17

  • Last stock! Liteplan DLP/1 , obsolete replaced by the ADM/1-K

    LITEPLAN Liteplan DLP/1 , obsolete replaced by the ADM/1-K

    Obsolete, this how been replaced with the ADM/1-K which will be supplied with a new smaller lithium battery   Replacement   A 3-hour emergency DALI self-test driver designed for constant current LED devices, supplied complete with extra long life LiFePO4 battery packs. This product is suitable for integral applications. The DLP/1 operates a single 4V chip at 550mA. In keeping with the DALI standard, this unit will revert to standalone self-test if not connected to a DALI operating system. For a full list of our compatible devices, please see our LED Device range.  This range operates with LiFePO4 battery technology, dramatically reducing energy consumption and facilities management labour due their long operational life.  DLP/1 DALI Addressable Range Specifications For Integral Use with Slim Batteries High Temperature Tolerance Batteries Extra Long Life LiFePO4 Batteries DALI Self-Test Module High Output (700mA) Version Available   DLP/1 Input Voltage 230-240 Volts AC – 50/60Hz Power Rating Charging Maintained: 32mA λ = 0.6 Standby Non-Maintained: 8mA λ = 0.15 Em. Duration 3-hours Battery Type IRF26650 LiFePO4 Battery Voltage 3.2V Battery Capacity 3.8Ah Charge Current Dual Rate 0-225mA Discharge Current 700mA nominal Recharge Time 24-hours TC Max 60°C Module / 55°C Battery Output Load 1 x 2W Output Current 550mA Module Dims. 149mm x 35mm x 28mm Battery Dimensions (with end caps) 220mm long x 22mm wide x 24mm high Fixing Centres 132mm x M4 Module Weight 0.1Kg Battery Weight 0.11Kg

    £76.80

  • Lite-Plan HRN/T5/4/14+24 KIT

    LitePlan Lite-Plan HRN/T5/4/14+24 KIT

    The Lite-Plan HRN/T5/4/14+24 is a 3hr emergency lighting conversion lit. Specifically designed for use with 14w & 24w T5 fluorescent lamps.4-pole change over relay plus additional 5th pole for HF ballast isolation. This Lite-Plan conversion kit has the following benefits :- Specific T5 lamp calibration to maximise BLF%, 4 pole changeover relay, additional 5th pole relay, Deep discharge protection, Low profile enclosure, constant current charger and high temperature NiCd cells. The HRN/T5 range is supplied in conversion kit form. They are supplied as standard with the following parts :- 500mm green charge healthy LED indicator and mounting collar, 4 Cell kits are supplied with T1 NiCd and 6-Cell with T3 NiCd batteries and AMP irreversible battery connector.

    £85.44

Login

Forgot your password?

Don't have an account yet?
Create account