Products
-
Philips HF-P 1 22-42 PL-T/C/L/TL5C EII 220-240V Philips
HF-Performer II for PL-T/C/R/L/TL5C lamps HF-Performer II for PL-T/C/R/L/TL5C lamps HF-P 1 22-42 PL-T/C/L/TL5C EII 220-240V HF-Performer EII PL-T/C/R/T5c is a sustainable, slim and high-frequency electronic ballast for a wide range of CFL- ni applications. It is ideal for applications where high energy efficiency is required. The HF-Performer EII range has a robust design, meets all relevant international safety and performance standards and is energy-efficient (CELMA EEI A2). Lamp type PL-T/C/L/TL5C Number of lamps 1 piece/unit Automatic restart Yes Operating and Electrical Input Voltage 220 to 240 V Input frequency 50 to 60 Hz Operating frequency (max.) - kHz
£19.21
-
PHILIPS HF-P 1/2 18 PL-T/C III 220-240V Single or Twin 18W PLC/T
View Datasheet General Information Application Code III Lamp Type PL-T/C Number of Lamps 2 piece/unit Number of Products on MCB (16A Type B) (Nom) 28 Automatic Restart Yes Operating and Electrical Input Voltage 220 to 240 V Input Frequency 50 to 60 Hz Operating Frequency (Max) - kHz Operating Frequency (Min) 42 kHz Operating Frequency (Nom) 45 kHz Ignition Method Warm Start Crestfactor (Max) 1.7 Power Factor 100% Load (Nom) 0.95 Ignition Time (Max) 0.40 s Mains Voltage Performance (AC) -8%-+6% Mains Voltage Safety (AC) -10%-+10% Earth Leakage Current (Nom) 0.5 mA Inrush Current Width 0.250 ms Constant Wattage Deviation -2%/+2% Ballast Factor (Nom) 1 Power Losses (Nom) 0.68-2.21 W Inrush Current Peak (Max) 18 A Efficiency at full load [%] 87.97 %
£19.21
-
PHILIPS HF-P 2 24/39 TL5 HO III 220-240V 50/60Hz
Operating and electrical Inrush current width 0.30 ms Line Frequency 50 to 60 Hz Inrush current peak (max.) 24 A Number of products on MCB (16 A type B) (nom.) 20 Input frequency 50 to 60 Hz Input Voltage 220 to 240 V View Datasheet
£19.96
-
PHILIPS HF-P 218/236 TL-D III 220-240V 50/60 Hz
Philips Electronic HF performer II TL-D ballast to run 2x18w T8 Tubes - HFP218/236TLDEII
£21.95
-
PHILIPS HF-P 218/236 TL-D III 220-240V 50/60 Hz
Philips Electronic HF performer II TL-D ballast to run 2x18w T8 Tubes - HFP218/236TLDEII
£21.95
-
PHILIPS HF-P 218/236 TL-D III 220-240V 50/60 Hz
Philips Electronic HF performer II TL-D ballast to run 2x18w T8 Tubes - HFP218/236TLDEII
£21.95
-
PHILIPS HF-R 2 14-35 TL5 EII 220-240V 50/60Hz
Product Features Flat, lightweight high-frequency electronic regulating ballast, using 1-10V protocol for TL5 fluorescent lamps Features Programmed start: flicker-free ignition < 0.5 seconds and striation-free operation, no stroboscopic effects. Preheating the lamp electrodes enables the lamps to be switched on and off without reducing life Smart power ensures constant light, independent of mains fluctuations Up to 60% reduction in energy consumption by using automatic lighting control systems Stop circuit is activated within 5 seconds in the event of lamp failure (safety stop), and ballast resets automatically after lamp replacement Application 1-10V installations with daylight linking and/or movement detection (for energy savings) 1-10V installations with remote control systems (combining energy savings with comfort) Installations with emergency back-up, according to IEC 60598-2-22
£74.74
-
PHILIPS HF-R 2 26-42 PL-T/C EII 220-240V 50/60Hz 1-10V Dimmable
913700626566 HF-R 2 26-42 PL-T/C EII 220-240V 50/60Hz Compact, high-frequency electronic dimming ballast, using the analog protocol (1-10 V) for PL-T, PL-C and PL-R lamps;The ballast is primarily designed for Indoor application. For outdoor application, the luminaire should be minimum ClassⅠand need to be sufficiently protected against water & dust. The installation should also be guard against any lightening surge or any other necessary electrical protection as deemed in such typical installation & application. Product data General information Application Code EII Type Version mk3 Lamp Type PL-T/C Number of Lamps 2 piece/unit Number of Products on MCB (16A Type B) (Nom) 12 Automatic Restart Yes Operating and electrical Input Voltage 220 to 240 V Input Frequency 50 to 60 Hz Operating Frequency (Max) 100 kHz Operating Frequency (Min) 40 kHz Ignition Method Programmed Start Crestfactor (Max) 1.7 Power Factor 100% Load (Nom) 0.95 Ignition Time (Max) 1.5 s Mains Voltage Performance (AC) -8%-+6% Mains Voltage Safety (AC) -10%-+10% Earth Leakage Current (Max) 0.5 mA Inrush Current Width 0.35 ms Constant Wattage Deviation -2%/+2% Ballast Factor (Nom) 0.99 Power Losses (Nom) 6.5-7.5 W Inrush Current Peak (Max) 45 A Efficiency at full load [%] 93.58 % Wiring Connector Type Input Terminals Insert Cable Capacity Output Wires Mutual (Nom) 30 pF Connector Type Output Terminals Insert Connector Type Control Input Terminals Insert Wire Striplength 7.5-8.5 mm Dual Fixture Master/Slave Not advisable [ Master/Slave operation not advised] Control Input Terminal Cross Section 0.50-1.50 mm² Input Terminal Cross Section 0.50-1.50 mm² Datasheet, 2022, January 14 data subject to change Lighting Lighting Output Terminal Cross Section 0.50-1.50 mm² Cable Capacity Output Wires to Earth (Nom) 75 pF System characteristics Rated Ballast-Lamp Power 26-42 W Temperature T-Ambient (Max) 50 °C T-Ambient (Min) -20 °C T-Storage (Max) 80 °C T-Storage (Min) -25 °C T-Case Lifetime (Nom) 65 °C T-Case Maximum (Max) 75 °C Stable Lamp Operation Temperature Not Specied T-Ignition (Max) 50 °C T-Ignition (Min) 0 °C Controls and dimming Control Interface 1-10V Regulating Level Power 1%-100% Control Input Protection Yes (Basic insulation) Mechanical and housing Housing S 123x79x33 Emergency operation Battery Voltage Lamp Ignition 198-254 V Battery Voltage Lamp Operation 176-254 Approval and application Energy Efficiency Index A1 BAT IP Classification IP 20 [ Ingress Protection 20] EMI 9 kHz ... 30 MHz EN55015 EMI 30 MHz ... 1000 MHz EN55022 level B Safety Standard IEC 61347-2-3 Performance Standard IEC 60929 Quality Standard ISO 9000:2000 Environmental Standard ISO 14001 Harmonic Current Emission Standard IEC 61000-3-2 EMC Immunity Standard IEC 61547 Vibration Standard IEC68-2-6 F c Bumps Standard IEC 68-2-29 Eb Humidity Standard EN 61347-2-3 clause 11 Approval Marks CE marking ENEC certicate VDE-EMV certicate Temperature Marking Yes Emergency Standard IEC 60598-2-22 Hum And Noise Level Inaudible Product data Full product code 872790080972500 Order product name HF-R 2 26-42 PL-T/C EII 220-240V 50/60Hz EAN/UPC - Product 8711500880758 Order code 913700626566 Numerator - Quantity Per Pack 1 Numerator - Packs per outer box 12 Material Nr. (12NC) 913700626566 Net Weight (Piece) 0.23
£63.08
-
PHILIPS HF-R 236 TL-D EII 220-240V 50/60Hz 1-10V Dimmable 2 x 36W
General Information Remarks UK importer address: Signify Commercial UK Limited, 3, Guildford Business Park, GU2 8XG Application code EII Type version mk2 Lamp type TL-D Number of lamps 2 piece/unit Number of products on MCB (16 A type B) (nom.) 12 Automatic restart Yes Operating and Electrical Input Voltage 220 to 240 V Input frequency 50 to 60 Hz Operating frequency (max.) 89 kHz Operating frequency (min.) 45 kHz Ignition method Programmed Start Crest factor (max.) 1.7 Power factor 100% load (nom.) 0.98 Ignition time (max.) 0.2 s Mains voltage performance (AC) -8%-+6% Mains voltage safety (AC) -10%-+10% Earth leakage current (max.) 0.5 mA Inrush current width 0.40 ms Power losses (nom.) 7.3 W Inrush current peak (max.) 45 A Efficiency at full load [%] 88.69 %
£53.34
-
PHILIPS HF-R TD 280 TL5/PL-L EII 220-240V 913700609666
Specifications General Information Remarks UK importer address: Signify Commercial UK Limited, 3, Guildford Business Park, GU2 8XG Application code E+ Type version mk1 Lamp type TL5/PL-L Number of lamps 2 piece/unit Number of products on MCB (16 A type B) (nom.) 9 Automatic restart Yes Operating and Electrical Input Voltage 220 to 240 V Input frequency 50 to 60 Hz Operating frequency (max.) - kHz Operating frequency (min.) - kHz Ignition method Warm Start Crest factor (max.) 1.7 Power factor 100% load (nom.) 0.95 Ignition time (max.) 0.2 s Mains voltage performance (AC) -8%-+6% Mains voltage safety (AC) -10%-+10% Earth leakage current (max.) 0.5 mA Inrush current width 0.35 ms Standby power consumption (max.) 0.25 W Ballast factor (nom.) 1.0 Power losses (nom.) 11.3 W Inrush current peak (max.) 35 A
£74.74
-
PHILIPS HF-Ri TD 1 14/21/24/39
Philips TL5 14-39w Single High Frequency Dali Dimmable Ballast from Philips Model: 913700698366 A Philips TL5 14-39w Single High Frequency Dali Dimmable Ballast Technical Specifications Control Gear Type High Frequency Accessory Type Ballast Wattage 39 W Manufacturer Philips Dimming? Dimmable No. Of Lamps Single (1x) Fixing Centers 350mm Height 28 mm Length 360 mm Type Control Gear Terminals 4 Width 30 mm Control Gear Technology Fluorescent
£52.38
-
PHILIPS HF-Ri TD 1 28/35/49/54 TL5 E+ 195-240V 66205100 Philips Dali
66205100 Specifications General Information Remarks UK importer address: Signify Commercial UK Limited, 3, Guildford Business Park, GU2 8XG Application code E+ Type version mk2 Lamp type TL5 Number of lamps 1 piece/unit Number of products on MCB (16 A type B) (nom.) 39 Automatic restart Yes Operating and Electrical Input Voltage 195-240 V Input frequency 50 to 60 Hz Operating frequency (max.) 110 kHz Operating frequency (min.) 45 kHz Ignition method Warm Start Crest factor (max.) 1.7 Power factor 100% load (nom.) 0.95 Ignition time (max.) 1 s Mains voltage performance (AC) -8%-+6% Mains voltage safety (AC) -10%-+10% Earth leakage current (max.) 0.5 mA Inrush current width 0.18 ms Standby power consumption (max.) 0.25 W Ballast factor (nom.) 1 Power losses (nom.) 3.8 W Inrush current peak (max.) 20 A Wiring Connector type input terminals WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring] Cable capacity output wires mutual (max.) 200 pF Connector type output terminals WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring] Connector type control input terminals WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring] Wire strip length 8.0-9.0 mm Dual fixture master/slave Yes [ Master/Slave operation possible] Control input terminal cross section 0.50-1.00 mm² Input terminal cross section 0.50-1.00 mm² Output terminal cross section 0.50-1.00 mm² Auto-insert (ALF/ADS) wire cross section 0.75 mm² Cable capacity output wires to earth (max.) 200 pF System characteristics Rated ballast-lamp power 28-35-49-54 W Rated lamp power on TL-D 58 W System power on TL-D 55.5 W Lamp power on TL-D 52.2 W Power loss on TL-D 3.3 W Rated lamp power on PL-L 55 W System power on PL-L 54.6 W Lamp power on PL-L 51.2 W Power loss on PL-L 3.4 W Rated lamp power on TL5 28/35/49/54 W System power on TL5 32.1/39.1/55.1/57.7 W Lamp power on TL5 29.4/36.4/51.6/54.8 W Power loss on TL5 2.7/3.0/3.5 W Rated lamp power on TL5 ECO 25/32/45/50 W System power on TL5 ECO 29.4/33.1/49.1/54.2/ W Lamp Power on TL5 ECO 26.3/30.2/45.7/50.4 W Rated lamp power on TL-D ECO 51 W System power on TL-D ECO 45.8 W Power loss on TL-D ECO 3.1 W Lamp power on TL-D ECO 42.7 W Power loss on TL5 ECO 3.1/2.9/3.4/3.8/ W Temperature T-ambient (max.) 50 °C T-ambient (min.) -25 °C T storage (max.) 80 °C T storage (min.) -40 °C T case lifetime (max.) 75 °C T-Case maximum (max.) 75 °C Stable lamp operation temperature 15°C T-Ignition (max.) 50 °C T-Ignition (min.) -25 °C Controls and Dimming Control interface TD Regulating level power 1%-100% Control input protection Yes (Basic insulation) Mechanical and Housing Housing L 359x30x21 Emergency Operation Battery voltage lamp ignition 198-254 V Battery voltage lamp operation 176-254 Approval and Application Energy efficiency index A1 BAT IP classification IP 20 [ Ingress Protection 20] EMI 9 kHz ... 30 MHz EN55015 EMI 30 MHz ... 1,000 MHz EN 55022 Class B Safety standard IEC 61347-2-3 Performance standard IEC 60929 Quality standard ISO 9000:2000 Environmental standard ISO 14001 Harmonic current emission standard IEC 61000-3-2 EMC immunity standard IEC 61547 Vibration standard IEC68-2-6 F c Bumps standard IEC 68-2-29 Eb Humidity standard EN 61347-2-3 clause 11 Approval marks CE marking ENEC certificate VDE-EMV certificate Temperature marking Yes Emergency standard IEC 60598-2-22 Humming and noise level Inaudible Product Data Full product code 871829166205100 Order product name HF-Ri TD 1 28/35/49/54 TL5 E+ 195-240V EAN/UPC – product 8718291662051 Order code 66205100 Local order code HFRITD12854T5PL SAP numerator – quantity per pack 1 Numerator – packs per outer box 12 SAP material 913700695666 SAP net weight (piece) 0.261 kg
£69.31