Please note this item is now obsolete , you will be sent a Philips alternative which is exactly the same size with the same terminals
This is the Tridonic PC 2/58 T8 Pro, a non-dimmable high frequency ballast to run 2 x 58w T8 fluorescent tube or 2 x 55w TC-L lamp.These ballasts have a nominal life time of up to 100,000 hours and provide a constant luminous flux even with fluctuations in mains voltage.Tridonic T8 Pro ballasts also have an automatic start after replacement of defective lamps and a safety shutdown of defective lamps at the end of a lamps life.
EM powerLED PRO DIM SR 45 W
Combined emergency lighting LED driver
Note: LED driver supplied with duration dip switch (2-way) in 3 hours position. Duration dip switch and I-SELECT 2 PLUG must be set before battery and mains connection.
Product description
Independent dimmable LED driver
Emergency lighting LED driver with DALI interface and automatic test function
For self-contained emergency lighting
For LED modules with a forward voltage of 20 – 50 V
SELV for output voltage < 60 V DC
Compact plastic casing with strain relief
Properties
Output power 6 – 45 W
Constant current LED operation
300 – 1,400 mA output current in mains operation, adjustable with I-SELECT 2 PLUG in steps of 25 mA or via DALI in steps of 1 mA
Integrated emergency lighting unit
1, 2 or 3 h rated duration
Operating time selectable with dip switch (2-way)
Automatic shutdown of output if the forward voltage of the LED is out of range
Two-colour status display LED
Electronic multi-level charge system
Pulse current charging for NiMH batteries
Polarity reversal protection for battery
Power-up fading at AC
Protective features (overtemperature, short-circuit, overload, no-load, input voltage range, reduced surge amplification)
Deep discharge protection
Short-circuit-proof battery connection
5 years guarantee
Interfaces
one4all (DALI DT 1 & 6, DSI, switchDIM, corridorFUNCTION)
Terminal blocks: 45° push terminals
Batteries
High-temperature cells
NiCd or NiMH batteries
D, Cs, LA or LAL cells
Battery box for independent use
4 year design life
1 year guarantee
For battery compatibility refer to data sheet
Digital Dimming Ballast to run 2 X 21/39w T5 tubes - PCA 2x21/39 T5 ECO - 22185102
Product description
Processor-controlled ballast with xitec II inside
Highest possible energy class CELMA EEI = A1 BAT (1)
Noise-free precise control via DALI or DSI signal, switchDIM or corridorFUNCTION
Nominal lifetime up to 100,000 h (at ta 50 °C with a failure rate ≤ 0.2 % per 1,000 h)
Multilamp management
OEM-specific reserved memory areas
5 years guarantee
Interfaces
DALI
DSI
switchDIM (with memory function + selectable dimming rate)
corridorFUNCTION (3 preprogrammed profiles)
Integrated SMART interface for function with SMART Sensor 5D 19f and corridorFUNCTION plugs
Functions
Intelligent Temperature Guard (overtemperature protection)
Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)
Optimum filament heating in any dimmer setting
Disconnection of filament heating from a dimming level of approx. 90 % for maximum energy efficiency (SMART-Heating concept)
corridorFUNCTION with ambient light control
Automatically triggered emergency lighting value in DC mode, 15 %
For emergency lighting systems as per EN 50172
Automatic start after replacement of defective lamps
Automatic shutdown if the lamp is faulty
Product description
Kit with emergency lighting LED driver, battery for 3 h duration and indication LED
For self-contained emergency lighting
For LED modules with a forward voltage of 10 – 54 V
SELV for output voltage < 60 V DC
Low profile casing (21 x 30 mm cross-section)
For luminaire installation
EM = Emergency
Driver LCBI 10W 180/350/500mA PHASE-CUT/1–10V SR
advanced series
Product description
Independent dimmable LED driver
Constant current LED driver
Dimmable via leading edge and trailing edge phase dimmers
Dimmable via 1 ... 10 V
Output dimmed analogue (current amplitude)
Dimming range typ. 10 to 100 % (depending on dimmer)
For luminaires of protection class I and protection class II
For luminaires with M and MM as per EN 60598, VDE 0710 and VDE 0711
Temperature protection as per EN 61347-2-13 C5e
SELV
Output current 180, 350 or 500 mA
Output power 10 W
Nominal lifetime up to 50,000 h
5 years guarantee
Housing properties
Casing: polycarbonate, white
Type of protection IP20
Screw terminal
Functions
Overload protection
Short-circuit protection
No-load protection
No output current overshoot at mains on/off
Tridonic Electronic Magnetic Choke 380 - 415v to run 2000w Metal Halide lamps - OGLI 2000W 180 B234
Igniter to suit
https://www.easy-controlgear.com/products/bag-380mzn2000s-bg-zg-bag-380-mzn-2000-s?_pos=1&_sid=3a8a957b0&_ss=r
Capacitor required
https://www.easy-controlgear.com/products/cap-60uf-450v-mst-025?_pos=3&_sid=72cf6ff12&_ss=r
Obsolete, If you are using the dali dimming feature please order the EL2X80IDIM , please note this is dali dimming only and not DSI dimming
Product description
Processor-controlled ballast with xitec II inside
Highest possible energy class CELMA EEI = A1 BAT (1)
Noise-free precise control via DALI or DSI signal, switchDIM or corridorFUNCTION
Nominal lifetime up to 100,000 h (at ta 50 °C with a failure rate ≤ 0.2 % per 1,000 h)
Multilamp management
OEM-specific reserved memory areas
5 years guarantee
Interfaces
DALI
DSI
switchDIM (with memory function + selectable dimming rate)
corridorFUNCTION (3 preprogrammed profiles)
Integrated SMART interface for function with SMART Sensor 5D 19f and corridorFUNCTION plugs
Functions
Intelligent Temperature Guard (overtemperature protection)
Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)
Optimum filament heating in any dimmer setting
Disconnection of filament heating from a dimming level of approx. 90 % for maximum energy efficiency (SMART-Heating concept)
corridorFUNCTION with ambient light control
Automatically triggered emergency lighting value in DC mode, 15 %
For emergency lighting systems as per EN 50172
Automatic start after replacement of defective lamps
Automatic shutdown if the lamp is faulty
Tridonic Combined Electronic ballast to run 3/4 x 14w T5 Combo (3h 3 Cell)
89800002
Rated supply voltage 220 – 240 VMains frequency 50 / 60 HzMains voltage changeover threshold according to EN 60598-2-22tc point max. 70 °CAmbient temperature ta 0 ... 50 °COperating frequency > 30 kHzBattery charging time 24 hCharge current 210 mADischarge current 1 h 2.4 ADischarge current 3 h 1.1 AMin. lamp starting temperature (normaloperation)-15 °CMin. lamp starting temperature (emergency mode)0 °CType of protection IP20
RANGE : INDOOROUTPUT CURRENT : 350MA-1050MAPOWER : 150WINPUT : 220-240VACEFFICIENCY : ≥95%POWER FACTOR : ≥0.98OPERATING FREQUENCY : 50/60HZFUNCTION : DALI DIMMERIP RATE : IP20DIMENSION : 425X30X28LIFE TIME : 50000HRSWORKING TEMP : -40°C~+70°CWARRANTY PERIOD : 5YEARSWARRANTY TYPE : REPLACESAFTY CLASS : I
Driver LC 81W 1200-1750mA flexC lp ADV
advanced series SELV
Product description
LED Constant current LED driver for luminaire installation
New version DC operating with EL marking
For luminaires of protection class I and protection class II
Temperature protection as per EN 61347-2-13 C5e
Output current adjustable between 1,200 – 1,750 mA
Max. output power 80.5 W
Up to 87 % efficiency
Nominal lifetime up to 100,000 h
5 years guarantee
Housing properties
Low profile metal casing with white cover
Type of protection IP20
Interfaces
Terminal blocks: 45° push terminals
Functions
Overload protection
Short-circuit protection
No-load protection
Overtemperature protection
Burst protection voltage 1 kV
Surge protection voltage 1 kV (L to N)
Surge protection voltage 2 kV (L/N to earth)
Suitable for emergency escape lighting systems acc. to IEC 50172
Typical applications
For linear/area lighting in office applications